IT Geluid Communicatie Kabels Licht Sets Rigging Special FX Video Conference Diversen Decor & Stage

Aphex Dominator II 720

NOMINAL OPERATING LEVEL 

(Peak Ceiling RANGE switchINPUT
Connector3-Pin XLR female (pin 1 ground, pin 2 positive, pin 3 negative)
Type Transformerless, servo balanced with passive 4th order RF filter Chassis grounded per AES standards

Impedance: 
19.5 k
Ω Unterminated;
600Ω with rear-panel terminator engaged (terminator lifts in bypass)

Nominal level:

0dBu (for use with +4 or +8dBu)
from 0dBu to +8dBu

-10dBu
-from -10dBu to 0dBu 

Maximal level:

0dBu (for use with +4 or +8dBu)
+26dBu 

-10dBu
+16dBu (+14.8dBV) 

CMRR:
> 50dB 20Hz to 10kHz

RF Rejection:
> 28dB at 800 kHz; > 60dB above 2 mHz

OUTPUT

Connector: 
3-Pin XLR male (pin 1 ground, pin 2 positive, pin 3 negative) 

Type: 
Transformerless, servo balanced, chassis grounded per AES standards 

Output Impedance: 
65Ω

Nominal Level:

0dBu (for use with +4 or +8dBu)
from 0dBu to +8dBu 

-10dBu
from -10dBu to 0dBu 

Maximum Level:

0dBu (for use with +4 or +8dBu)
+25dBu peak value of sine wave

-10dBu
+15dBu PK* 

AUDIO (Controls set for unity gain, no limiting and flat response except as otherwise noted) 

Frequency Response:
+0.2dB 4.5Hz - 50kHz 

Dynamic Range:

0dBu (for use with +4 or +8dBu)
> 108dB

-10dBu
>106dB

Hum & Noise (unweighted, 22 Hz - 22 kHz): 

0dBu (for use with +4 or +8dBu)
< -82dBu

-10dBu
< -90dBu

Crosstalk:
< -60dB up to 10kHz 

THD (Ref.: 1kHz, no limiting):

0dBu (for use with +4 or +8dBu)
< 0.006% (+12dBu in) 

-10dBu
< 0.006% (+2dBu in) 
 

SMPTE IMD:
0dBu (for use with +4 or +8dBu)
< 0.006% (+12dBu in) 

-10dBu
< 0.006% (+2dBu in) 

INPUT GAIN:
+14/-21 dB typical

720 CONTROL & METERING PARAMETERS (on front panel unless otherwise noted) 

PROCESS ON/OFF:
ON: Active / OFF: Hardwire Bypass

LF EQ Boost/Cut:
± 5 dB

HF EQ Boost/Cut:
± 5 dB

XOVER 1 Frequency:
100 Hz / 210 Hz

XOVER 2 Frequency:
1.7 kHz / 3.4 kHz

RELEASE Time:
150 mSec to 7 Sec

RCH (Relative Crest Height) DENSITY: STEREO COUPLING:
-5 to +5

 

STEREO COUPLING:
ON/OFF

PEAK CEILING: 

0dBu (for use with +4 or +8dBu)
+1 to +25dBu (PK)**
Peak Ceiling is adjusted with the COARSE (2dB steps), FINE (0.2dB steps) and RANGE (0dB/-10dB) controls


-10dBu
-9 to +15dBu (PK)

LIMITING Meter: 
10 segment meter indicates up to 15dB of gain reduction in the channel with the greatest amount of limiting.

600 OHM INPUT TERMINATION: 
Each channel is switchable on rear panel (lifts in bypass)

REMOTE Control Jack: 
A four pin RJ11 telephone-style connector on the rear panel provides remote control capacity of the PROCESS ON/OFF bypass relays and dry “tally” contact for a remote status indicator 

722 CONTROL PARAMETERS

NOMINAL OPERATING LEVEL 

(Peak Ceiling RANGE switchINPUT
Connector3-Pin XLR female (pin 1 ground, pin 2 positive, pin 3 negative)
Type Transformerless, servo balanced with passive 4th order RF filter Chassis grounded per AES standards

Impedance: 
19.5 k
Ω Unterminated;
600Ω with rear-panel terminator engaged (terminator lifts in bypass)

Nominal level:
from 0dBu to +8dBu

Maximal level:
+26dBu 

CMRR:
> 50dB 20Hz to 10kHz

RF Rejection:
> 28dB at 800 kHz; > 60dB above 2 mHz

OUTPUT

Connector: 
3-Pin XLR male (pin 1 ground, pin 2 positive, pin 3 negative) 

Type: 
Transformerless, servo balanced, chassis grounded per AES standards 

Output Impedance: 
65Ω

Nominal Level:
from 0dBu to +8dBu 

Maximum Level:
+25dBu peak value of sine wave

 

AUDIO (Controls set for unity gain, no limiting and flat response except as otherwise noted) 

Frequency Response:
+0.2dB 4.5Hz - 50kHz 

Dynamic Range:
> 108dB

Hum & Noise (unweighted, 22 Hz - 22 kHz): 
< -82dBu

Crosstalk:
< -60dB up to 10kHz 

THD (Ref.: 1kHz, no limiting):
< 0.006% (+12dBu in) 

SMPTE IMD:
< 0.006% (+12dBu in) 

INPUT GAIN:

+14/-21 dB typical

720 CONTROL & METERING PARAMETERS (on front panel unless otherwise noted) 

PROCESS ON/OFF:
ON: Active / OFF: Hardwire Bypass

LF EQ Boost/Cut:
± 5 dB

HF EQ Boost/Cut:
± 5 dB

XOVER 1 Frequency:
100 Hz / 210 Hz

XOVER 2 Frequency:
1.7 kHz / 3.4 kHz

RELEASE Time:
150 mSec to 7 Sec

RCH (Relative Crest Height) DENSITY: STEREO COUPLING:
-5 to +5

 

STEREO COUPLING:
ON/OFF

PEAK CEILING: 
+1 to +25dBu (PK)**
Peak Ceiling is adjusted with the COARSE (2dB steps), FINE (0.2dB steps) and RANGE (0dB/-10dB) controls

LIMITING Meter: 

10 segment meter indicates up to 15dB of gain reduction in the channel with the greatest amount of limiting.

600 OHM INPUT TERMINATION: 
Each channel is switchable on rear panel (lifts in bypass)

REMOTE Control Jack: 
A four pin RJ11 telephone-style connector on the rear panel provides remote control capacity of the PROCESS ON/OFF bypass relays and dry “tally” contact for a remote status indicator 

OTHER SPECIFICATIONS:

Power Input:

IEC standard receptacle with voltage selector, fuse and filter 

Power Requirements: 
100, 120, 220, or 240 VAC; 50 or 60 Hz

Power Consumption:
30 watts maximum

Power Fuse:
Slow blowing type- 100/120 VAC: 0.375 A; 220/240 VAC: 0.25A 

Net Weight:
6 lbs. (2.72 kg) 

Dimensions:
19” W x 1.75” H x 9.63” D (482.6 mm x 44.5 mm x 244.6 mm)


OTHER SPECIFICATIONS:

Power Input:
IEC standard receptacle with voltage selector, fuse and filter 

Power Requirements: 
100, 120, 220, or 240 VAC; 50 or 60 Hz

Power Consumption:
30 watts maximum

Power Fuse:
Slow blowing type- 100/120 VAC: 0.375 A; 220/240 VAC: 0.25A 

Net Weight:
6 lbs. (2.72 kg) 

Dimensions:
19” W x 1.75” H x 9.63” D (482.6 mm x 44.5 mm x 244.6 mm)

Locatie Dordrecht
Verhuurder Rick Bakker Productions
Afstand
Aantal beschikbaar 2 stuk(s)
Prijs p/d € 12,50
  In winkelwagen