Type: Cardioid condenser (electret bias)
Frequency Response: 40 to 20,000 Hz
Output Impedance
- Rated at 150 ohms (90 ohms actual)
- Recommended minimum load impedance: 800 ohms
- (May be used with loads as low as 150 ohms with reduced clipping level)
Output Level (at 1,000 Hz)
- Open Circuit Voltage . . . . . . . . . . . . . -80.0 dB (0.10 mV)
0 dB = 1V/μbar
Preamplifier Output Clipping Level (at 1,000 Hz, less than 0.1% THD):
- 800 ohm load . . . . . . . . . . . . . . . . . . . . . . . . . 0 dBV (1.0V)
- 150 ohm load . . . . . . . . . . . . . . . . . . . . . . -13 dBV (0.22V)
Maximum SPL (at 1,000 Hz)
- 800 ohm load . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 155 dB
- 150 ohm load . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 145 dB
Hum Pickup: -5 dB equivalent SPL in 1 m0e field (60 Hz)
Output Noise
- 34 dB SPL, A-weighted
- 37 dB SPL, weighted per DIN 45 405
Signal-to-Noise Ratio: 64 dB re 94 dB SPL
Dynamic Range: 121 dB
Phasing: Positive pressure on diaphragm produces positive voltage on pin 2 relative to pin 3 of preamplifier output
connector
Power:
- Battery: Two 9-Vdc alkaline (NEMA 1604A), approximately 300 hours continuous with fresh alkaline batteries
- Simplex (Phantom) Voltage: 11 to 52 Vdc, operational down to 9 Vdc; 1.8 mA current drain; permissible to use simplex power with batteries in place or removed
Environmental Conditions
- Operating Temperature: -18° to 57° C
- Storage Temperature: -29° to 74° C
- Relative Humidity (Operating or Storage): 0 to 95%
Dimensions: 150 x 70 mm
Net Weight
- Microphone: 12 grams less cable
- Preamplifier: 435 grams less batteries