IT Geluid Communicatie Kabels Licht Sets Rigging Special FX Video Conference Diversen Decor & Stage

Lab Gruppen PLM 12K44

General
  • Processing / Network: Lake / Dante
  • Number of amplifier channels: 4
  • Total burst power all channels (share among channels with RPM): 12000 W

Max output power (all channels driven)
  • 2 ohms: 3000W
  • 2.67 ohms: 3000W
  • 4 ohms: 3000W
  • 8 ohms: 1900W
  • 16 ohms: 950W
  • Hi-Z 70 V: 3000W
  • Hi-Z 100 V: 3000W

Max output power single channel
  • 2 ohms: 4400W
  • 2.67 ohms: 5900W
  • 4 ohms: 4600W
  • 8 ohms: 2300W
  • 16 ohms: 1150W
  • Hi-Z 70V: 3300W
  • Hi-Z 100V: 4700W

Amplifier output modules (all models, all channels)
  • Peak output voltage: 194V
  • Max. output current: 67A
  • Rational Power Management (RPM): Regardless of model, any channel has potential to deliver the max single channel output power
  • Default voltage limitation (can be lifted with RPM configuration): 175 V
  • Protection features: Current Average Limiter (CAL), Very High Frequency Protection (VHF), Direct Current Protection (DC), Short Circuit Protection, Current-Clip Limiter, Voltage Clip Limiter, Temperature protection

Audio Performance (Amplifier platform with digital input)
  • THD + N 20 Hz - 20 kHz for 1 W: < 0.05 %
  • THD + N at 1 kHz and 1 dB below clipping: < 0.04 %
  • Dynamic range: > 114 dB
  • Channel separation (Crosstalk) at 1 kHz: > 70 dB
  • Frequency response (1 W into 8 Ohm, 20 Hz - 20 kHz): +/- 0.05 dB
  • Internal Sample Rate / Data path: 48 / 96 kHz / 32 bit floating point
  • Product propagation delay AES 96 kHz / analog input: 1.61 / 1.68 ms

Lake processing
  • Loudspeaker processing: Up to 4 modules of Classic/linear-phase/FIR crossover, EQ, delay, LimiterMax™ - peak and RMS limiters
  • System tuning: Group control with Raised Cosine™ MESA EG™ asymmetric filters
  • Input redundancy / Matrix: Automatic 4 level input redundancy / 4 input mixers
  • System integration: Comprehensive 3rd party protocol over UDP Ethernet

Measurement & Analysis
  • Pilot tone generation and analysis: Yes
  • Load impedance analysis: Yes
  • Real Time Analyzer (RTA), 3rd party integration: Yes

Dante Audio Network
  • Dante I/O: 8 x 8
  • Network topology / redundancy: Flexible topology / Supports daisy-chained and Dual redundant networks
  • Sample Rates / Transport: 48, 96 kHz / Uni + Multicast
  • Network latency: 0.25, 0.5, 1.0, 2.0, 5.0 ms

Device presets
Local memory locations for the settings of the product: 100

AES Inputs
  • Inputs: 4 AES inputs
  • Supported sample rates / resolution: 44.1, 48, 88.2, 96, 176.4, 192 kHz / up to 24 bits
  • Sample rate conversion THD+N 20 Hz - 20 kHz unweighted: 0.00003 %

Analog Inputs
  • Inputs: 4 high quality inputs with Iso-Float ground isolation
  • Maximum input / digital reference: +26 dBu / +21 dBu
  • Sampling rate / Resolution: 96 kHz / 24 bit
  • Input impedance balanced / unbalanced: 20 / 10 kOhm
  • THD+N (typical at 1 kHz unweighted): 0.00022 %
  • THD+N (typical at 20 Hz and 20 kHz unweighted): 0.00033 %

Limiters
  • Adjustable Inter-Sample Voltage Peak Limiter (ISVPL): 17.8 - 194 V, step size 0.1 V
  • Current Peak Limiter < 300 ms: 67 A peak
  • Current Average Limiter (CAL) > 300 ms: 33 Arms
  • MaxRMS (rms voltage limiter): Yes
  • MaxPeak (peak voltage limiter): Yes

Gain
  • Amplifier gain: 22 - 44 dB, step size 0.1 dB
  • Output attenuator: -Inf to 0 dB, step size 0.25 dB

Back panel Interface
  • Analog, 2-channel I/O (input + link): 4 x 3-pin XLR, electronically balanced
  • AES / EBU / I/O (input + link): 2 x 3-pin XLR
  • Output connectors: Neutrik speakON (1 x NLT8, 2 x NLT4) or 4 Binding Posts (pairs)
  • Auto 10/100, Auto Uplink: 2 x RJ45 etherCON
  • Control and monitoring interface: Via Ethernet for Lake Controller software, or DLM (the 3rd party protocol)
  • Detachable mains cord: Neutrik PowerCon rated at 250V/32A
  • Cooling: Three fans, front-rear airflow, temperature controlled speed

Front-panel user interface
  • Display: 2.5 inch, black / white, daylight readable LCD
  • Fault/Warning/Limit/Clip indicators: RGB LEDs and detailed fault description on display
  • Mute and soft function: buttons 8 provided
  • Standby Power button: On/Standby
  • Mute Enable button: Enables muting of outputs and inputs via soft-button keypad
  • Meter button: Toggles through meter views
  • Menu button: Provides a menu driven interface for full function front panel control
  • Rotary Encoder: Yes
  • Exit Button: Provides a “back” function

Mains Power
  • Nominal voltage: 100 - 240 Volt AC 45 - 66 Hz
  • Operating voltage: 70-265 V AC
  • Mains wall plug: NEMA L5-30 "Twist lock" 125 V / 30 A, and CEE 7/7 "Schuko" 230 V / 16 A

Power supply features
  • Soft start / Inrush power: Yes/ Max 8 Ampere
  • Power Factor Correction (PFC): 0.98
  • Regulated switch mode power supply (R.SMPS): Yes
  • Breaker Emulation Limiter (BEL): Configurable current threshold and breaker profile
  • BEL max current threshold: 25 A
  • Power Average Limiter (PAL): Yes
  • Under Voltage Limiter (UVL): Yes
  • Mains undervoltage and overvoltage protection and mains glitch tolerance: Yes

Dimensions
  • Rack rail to rear panel: W: 483 mm (19"), H: 88 mm (2 U), D: 424 mm (16")
  • Overall depth front-rear support: D: 498 mm (19.6")

Weight: 16.5 kg
 
Locatie Haarlem
Verhuurder React Audiovisueel
Afstand
Aantal beschikbaar 0 stuk(s)
Prijs p/d € 75,00
  In winkelwagen