Acoustical
  • Operating Frequency Range: 70Hz–20 kHz
  • Frequency Response: 76Hz–18 kHz ±4 dB
  • Phase Response: 250Hz–18 kHz ±45°
  • Maximum Peak SPL: 126 dB
  • Dynamic Range: >110 dB
  • Coverage: 80° x 50°
  • Crossover: 3,5kHz

Transducers
  • Low Frequency
    • One 8" cone driver with neodymium magnet
    • Nominal impedance: 4Ω
    • Voice coil size: 1.5"
    • Power-handling capability: 300 W (AES
  • High Frequency
    • One 2" compression driver
    • Nominal impedance: 12Ω
    • Voice coil size: 2"
    • Diaphragm size: 2"
    • Exit size: 0.75"
    • Power-handling capability: 100 W
Audio Input
  • Type: Differential, electronically balanced
  • Maximum Common Mode Range: ±15 V DC, clamped to earth for voltage transient protection
  • Connectors: Female XLR input with male XLR loop output
  • Input Impedance: 10 kΩ differential between pins 2 and 3
  • Wiring
    • Pin 1: Chassis/earth through 220 kΩ, 1000 pF, 15 V clamp network to provide virtual ground lift at audio frequencies
    • Pin 2: Signal +
    • Pin 3: Signal - (optional polarity reversal switch)
    • Case: Earth ground and chassis
  • DC Blocking: Differential DC blocking up to maximum common mode voltage
  • CMRR: >50 dB, typically 80 dB (50–500 Hz)
  • RF Filter: Common mode: 425 kHz; Differential mode: 142 kHz
  • TIM Filter: <80 kHz, integral to signal processing
  • Nominal Input Sensitivity: 0 dBV (1 V rms, 1.4 V peak) continuous average is typically the onset of limiting for noise and music
  • Input Level: Audio source must be capable of producing +20 dBV (10 V rms, 14 V peak) into 600Ω to produce maximum peak SPL over the operating bandwidth of the loudspeaker
Amplifier
  • Type: Two-channel complementary MOSFET output stages (class AB/bridged)
  • Output Power: 300 W total
  • THD, IM, TIM: <.02%
  • Load Capacity: 4Ω low channel, 12Ω high channel
  • Cooling: Forced air cooling over amplifier heatsink
AC Power
  • Connectors: PowerCon with looping output
  • Voltage Selection: Automatic
  • Safety Agency Rated Operating Range: 100–240 V AC; 50/60 Hz
  • Turn-on and Turn-off Points:  90–264 V AC; 50/60 Hz
  • Current Draw:
    • Idle Current: 0.448 A rms (115 V AC); 0.285 A rms (230 V AC); 0.497 A rms (100 V AC)
    • Maximum Long-Term Continuous Current (>10 sec): 2.55 A rms (115 V AC); 1.55 A rms (230 V AC); 2.75 A rms (100 V AC)
    • Burst Current (<1 sec): 2.90 A rms (115 V AC); 1.70 A rms (230 V AC); 3.20 A rms (100 V AC)
    • Ultimate Short-Term Current: 12.0 A peak (115 V AC); 9.0 A peak (230 V AC); 13.0 A peak (100 V AC)
    • Inrush Current: 15.0 A peak (115 V AC); 13.0 A peak (230 V AC); 15.0 A peak (100 V AC)
Locatie GRONINGEN
Verhuurder Bano
Afstand
Aantal beschikbaar 8 stuk(s)
Prijs p/d € 45,00